Skip to content

Landlord EICRs.

An Electrical Installation Condition Report (EICR) is a thorough inspection and test of a property’s fixed wiring: the consumer unit, circuits, sockets, switches and fixed equipment. For most private rented homes in England it is a legal requirement at least every five years.

Who needs an EICR?

Under the Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020, private landlords must have the electrical installation in each rented property inspected and tested by a qualified person at least every five years, or sooner if the last report recommends it.

That includes houses in multiple occupation (HMOs). Blocks of flats also need their communal areas testing: landlord supplies to stairwells, corridors, door entry, car park and external lighting.

  • Private landlords and letting agents managing tenancies
  • HMO landlords
  • Block managers and residents’ management companies, for the communal supply
  • Homeowners selling, buying or renovating

What the regulations require

  • A copy of the report to existing tenants within 28 days of the inspection.
  • A copy to new tenants before they move in.
  • A copy to the local authority within 7 days if they ask for one.
  • Any remedial or further investigation work completed within 28 days, or sooner if the report says so, with written confirmation to the tenant and the local authority.

Fines for breaches can reach £30,000, so it pays to keep on top of renewal dates. We can remind you when each property is next due.

What happens on the day

Derek will inspect the consumer unit and a sample of accessories, then test each circuit. The power will be off for short periods, so we will let the tenant know beforehand. A typical flat takes two to four hours.

You then receive a digital report with the overall result, Satisfactory or Unsatisfactory, and any observations coded:

  • C1: danger present, immediate action needed
  • C2: potentially dangerous, urgent remedial work needed
  • C3: improvement recommended
  • FI: further investigation needed without delay

Any C1, C2 or FI makes the report unsatisfactory. We will explain what each item means, quote for the work and issue confirmation once it is put right.

Common questions

How long is an EICR valid for?

For rented homes, up to five years. The inspector may recommend a shorter interval depending on the condition of the installation, in which case the shorter date applies.

Is an EICR the same as a landlord electrical safety certificate?

Yes. "Landlord electrical safety certificate" is the common name for an EICR carried out on a rented property.

Do I need to be there?

No. Many agents and landlords simply arrange access, and we liaise with the tenant directly. The report is emailed to you afterwards.

Can you do the remedial work too?

Yes. We can quote for and carry out any remedial work found, then issue the paperwork you need to show it has been completed.

Let’s keep your properties compliant.

Call Derek on 07482 242 565, email info@heavenelectrical.co.uk, or send a few details and he will get back to you.